0 items in your bag

 
Lead & Termination Options


All the information listed below needs to be concidered when creating your part number.


Lead Wire Code Definition
Spiral Lock Cable 1 Spriral lock armer cable
Spring Armored Cable N Spring Armored Cable is 0.250" diameter over fused Teflon® stranded and twisted singles with reinforced Mini-plug and strain relief. May be added to any thermocouple sensor when placing order.
Standard Cable 0 32" length, thermocouple grade #20 gauge stranded wire, Teflon® insulated and twisted with stainless steel woven overbraid.
Extension Leads ET Extender Leads are used to increase sensor lead length. They are available in any length and termination. Click here to order online.
Termination Code Definition
Mini-plug & Mini-jack M EDL color coded thermocouple connectors are constructed from thermocouple contact materials for digital instruments. Our Mini-plugs are availablein any thermocouple type and low and high temperature configuration to suit any application.
Phonoplug P The Phonoplug is designed for use with our NMP Pocket-Probe Series Analog Pyrometers. Our analog meters are passive devices and require no batteries or external power source. Supplied in type E thermocouple. (T/C type E)
Coil Cord w/ Mini-plug C PVC coil cord, 1' extends to 5'.
(with Mini-plug) for digital instruments
Standard Plug L

EDL color coded thermocouple connectors are constructed using only the finest grade thermocouple contact materials. Our standard plugs are available in low and high temperature versions to suit any application.

Spade Lugs A Non-insulated connectors designed to take the heat in any application for any analog instrument using screw terminals.
BET Plug E

Thermocouple tips in E style plug directly into digital instruments. There is a $23.00 savings when you purchase the E thermocouple tip. You may use an HBET holder where a lead is required. Various sensor tips mounted directly on Mini-plug.

DRT Plug R Thermocouple tips in R style fit into a HDRT holder. You save $23.00 on each R tip since you only require one holder which accommodates the various tips. For both analog and digital instruments.


Base Thermocouple Metals


Thermocouple Type Composing Materials Body Color Temperature Range
K Chromel vs. Alumel Yellow -450° to +2500° F
J Iron vs. Constantan Black -350° to +2192° F
E Chromel vs. Constantan Purple -454° to +1832° F
T Copper vs. Constantan Blue -454° to +752° F
N Nicrosil vs. Nisil Orange -454° to +2372° F